How modern performance tests revealed critical errors in a customer’s system shortly before go-live – and what you can learn from this for your own projects.
Performance Engineering | Practical report
The release date is set, the functional tests are green, the team is convinced: „It works.“ But what happens when hundreds of users simultaneously collect data on a normal working day? When everyone comes at once after an advertising campaign? Or when the system is under load for five hours straight? Exactly these questions we answered six weeks before the go-live of a new software for a client. The result surprised everyone.
Information about data protection: For data protection reasons, all customer data has been anonymized. The customer name, product designations, system names, and server information are presented in generalized form. The measured values mentioned are derived from the actual project.
Initial position
Anyone familiar with performance tests from the textbook assumes a ready-made testing environment, existing monitoring, and clear service level agreements. The reality was different, but we were able to solve it.
In addition, there were complicating factors: permissions were only granted after a lengthy process, many approvals were required, and time was tight. The architecture was anything but trivial – microfrontends, microservices, an external identity provider for logging in and event streaming in the background.
Nevertheless, the end result was clear: reliable results and critical findings – before the release, not after.
Methodology
Classic load tests often end with a single number: „The system can handle 300 users.“ Modern performance engineering works differently. It starts with the questions that the business really asks and chooses the appropriate testing method for each question. Five principles have shaped this project:
Test design
A single load test would never have found the critical errors. Only the combination of five backend scenarios and three complementary scenarios provided the complete picture:
Results
By 200 simultaneous users, the system scaled up admirably: twice as many users, twice as many completed requests. After 250 users, the picture changed. The throughput hardly improved any further; the wait time (P95) rose from 2.1 to 15 and finally to 42 seconds. The reason: The compute power of the on-demand service was reaching its limits.

During the long-term test, everything initially ran normally. However, the search for offers gradually became slower, from 0.35 to 1.0 seconds. After about 2.5 hours, the total failure occurred: database access broke down, the error rate was around 75 percent, and the system could no longer recover until the end of the test.

Two sources of error could be corrected during the testing phase and confirmed through repeated runs:
Without these findings, many employees might not have been able to log in at all on the release day, or would have logged out after an hour.
In parallel with 200 virtual users, a real browser opened the interfaces and measured when the page is visible and operable:
| Surface | Low load (20 users) | Under load (200 users) |
|---|---|---|
| Home page | 0.85 s | 1.5 s |
| Transaction XY | 1.89 s | 3.96 s |
| Transaction XZ | 0.67 s | 1.23 s |
Two vulnerabilities were discovered: During the approximately two-second transaction, the user did not see any charging status, clicked again, and triggered duplicate requests. Additionally, the interface called multiple interfaces in succession instead of in parallel, resulting in the added wait times. The development has fixed the second problem during the testing phase.
Auto-scaling is one of the great promises of modern platforms: As the load increases, the platform automatically scales up. We wanted to know whether this promise holds up under real-world load. To test this, we gradually increased the load from 50 to 400 users and observed whether the most computationally intensive service would automatically start additional instances.

The autoscaling was active – but it acted like a fire department that only starts working when it has been burning for two minutes, then thinks for another minute and then needs five minutes to get to the scene. It takes about eight minutes for a new instance to actually take over the load.

During the stress test, the load increased by 50 users every ten minutes. Before the scaling could take effect, the next level had already been reached – a third instance was never launched. The entire load continued to run on two instances, which reached their CPU limits at 250 users. The result is shown in the congestion zone in Figure 2: The wait time increased from 2 to 15 seconds.
The adjusting screws: Set thresholds earlier, shorten the observation window, optimize the start time of new instances, and prepare enough instances in advance for known peak times. Only a further Autoscaling test will show whether this works.
Disruptions happen: containers fall off, servers are restarted, deployments go wrong. The question is not whether it happens, but how the system reacts. Therefore, in the resilience test we deliberately created chaos, following the principle of chaos engineering: under constant load of 140 users, an instance of the service was stopped hard in minute 30.

The good news: The second instance took over. The bad news: By then, 1 minute and 40 seconds had passed, during which 134 requests were lost – more than one request per second. Behind each of them is an employee who was just collecting data, perhaps with the customer at the table.
The solution is relatively simple: health and liveness checks that detect a failed instance and automatically restart it. The feedback went directly to the development team – long before a real failure could have forced it.
Review
At normal load, the system is stable and reproducible and can be measured. However, with continuous and high load, database access is interrupted. The cause has been identified and the solution is planned. Above all, there is now a reliable planning basis: around 200 users in continuous operation, around 250 temporarily – without additional scaling.

Practical tips
Use
Training
The approach described here is not a secret, but rather a teachable methodology. In our hands-on training sessions, experienced consultants—who have carried out such projects themselves—provide the exact skills that made the difference in this project:
About the author
Principal IT Consultant | accompio
Tamer Ilgüz has more than ten years of experience in performance engineering. He plans, builds, and operates load and performance tests for complex distributed system landscapes – from microservice architectures to cloud platforms and business-critical application pipelines – and has been responsible for projects for renowned customers from various industries.
As a trainer at accompio, he shares this knowledge: methodology, theory, and tools of performance engineering – practically, with real examples from projects like this one.